    HD-A2FM Axial Piston Fixed Motor Ordering Code

     

    image.png

    HD-A2FM Axial Piston Fixed Motor Ordering Code .png

    HD-A2FM Axial Piston Fixed Motor Ordering Code .png

    HD-A2FM Axial Piston Fixed Motor Technical Data

    Shaft seal…Permissible pressure loading

    The service life of the shaft seal is influenced by the speed of the axial piston unit and the case drain pressure (case pressure).

    The mean differential pressure of 2 bar between the case and the ambient pressure may not be enduringly exceeded at normal

    operating temperature.

    For a higher differential pressure at reduced speed, see diagram.

    Momentary pressure spikes (t < 0.1 s) of up to 10 bar are permitted. The service life of the shaft seal decreases with an

    increase in the frequency of pressure spikes.

    The case pressure must be equal to or higher than the ambient pressure.

    1620790791163322.png

    Temperature range

    The FKM shaft seal may be used for case drain temperatures from -25 °C to +115 °C

    For application cases below -25 °C, an NBR shaft seal is required (permissible temperature range -40 °C to +90 °C). State NBR

    shaft seal in plain text when ordering. Please contact us.

    Direction of flow

     

    Direction of rotation, viewed on drive shaft Direction of flow
    clockwise (R) A → B
    counter-clockwise (L) B  → A

     

    Sizes 250 355 500
    qv flush   (l/min) 10 16 16

    Ports Port for Diagram

    A, B

    T

    Working port

    Drain port

     

    image.pngAxial Piston Fixed Pump HD-A2FM 7

    image.png

    image.png

    image.png

    image.png

    image.png

    Axial Piston Fixed Pump HD-A2FM 13Ports Port for Standard 6) Size 3) P Max [bar] 4) State 7)
    A , B Working port DIN 3852 M18 x 1.5 deep 12 350 O
    T 1 Drain port DIN 3852 M10 x 1 deep 8 3 O
    T 2 Drain port DIN 3852 M10 x 1 deep 8 3 O

    image.png

    Ports Port for Standard Size 3) P Max [bar] 4) State 8)
    A , B Working port   see port plates 450  
    T 1 Drain port DIN 3852 5) M12 x 1.5 deep 12 3 X 7)
    T 2 Drain port DIN 3852 5) M12 x 1.5 deep 12 3 O 7)

    image.png

    Plate Ports Port for Standard Size 1) P Max [bar] 2) State 5)
    03 A , B Working port DIN 3852 3) M22 x 1.5 deep 14 450 X
    04 A , B Working port DIN 3852 3) M22 x 1.5 deep 14 450 O

    Axial Piston Fixed Pump HD-A2FM 16Axial Piston Fixed Pump HD-A2FM 17Note

    1) For the maximum tightening torques the general instructions must be observed .

    2) Momentary pressure spikes may occur depending on the application. Keep this in mind when selecting measuring devices and fittings.

    3) The spot face can be deeper than specified in the appropriate standard

    5) O = Must be connected (plugged on delivery)   X = plugged (in normal operation)

    image.png

    Ports Port for Standard Size 3) P Max [bar] 4) State 8)
    A , B Working port   see port plates 450  
    T 1 Drain port DIN 3852 5) M16 x 1.5 deep 12 3 X 7)
    T 2 Drain port DIN 3852 5) M16 x 1.5 deep 12 3 O 7)

    image.png

    Plate Ports Port for Standard Size 1) P Max [bar] 2) State 5)
    01, 02, 10 A , B

    Working port

    Fastening thread

    SAE J518 4)

    DIN 13

    1/2”

    M8 x 1.25 deep 15

    450 O
    03 A , B Working port DIN 3852 3) M27 x 2 deep 16 450 X
    04 A , B Working port DIN 3852 3) M27 x 2 deep 16 450 O

    Note

    1) For the maximum tightening torques the general instructions must be observed .

    2) Momentary pressure spikes may occur depending on the application. Keep this in mind when selecting measuring devices and fittings.

    3) The spot face can be deeper than specified in the appropriate standard

    4) Only dimensions according to SAE J518, metric fastening thread is a deviation from standard.

    5) O = Must be connected (plugged on delivery)   X = plugged (in normal operation)

    image.png

    image.png

    Plate Ports Port for Standard Size 1) P Max [bar] 2) State 5)
    01, 02, 10 A , B

    Working port

    Fastening thread

    SAE J518 4)

    DIN 13

    3/4”

    M10 x 1.5 deep 17

    450 O
    04 A , B Working port DIN 3852 3) M33 x 2 deep 18 450 O

    image.png

    Ports Port for Standard Size 3) P Max [bar] 4) State 8)
    A , B Working port   see port plates 450  
    T 1 Drain port DIN 3852 5) M18 x 1.5 deep 12 3 X 7)
    T 2 Drain port DIN 3852 5) M18 x 1.5 deep 12 3 O 7)

    image.png

    Plate Ports Port for Standard Size 1) P Max [bar] 2) State 5)
    01, 02, 10 A , B

    Working port

    Fastening thread

    SAE J518 4)

    DIN 13

    3/4”

    M10 x 1.5 deep 17

    450 O
    04 A , B Working port DIN 3852 3) M33 x 2 deep 18 450 O

    Note

    1) For the maximum tightening torques the general instructions must be observed .

    2) Momentary pressure spikes may occur depending on the application. Keep this in mind when selecting measuring devices and fittings.

    3) The spot face can be deeper than specified in the appropriate standard

    4) Only dimensions according to SAE J518, metric fastening thread is a deviation from standard.

    5) O = Must be connected (plugged on delivery)   X = plugged (in normal operation)

    image.png

    Ports Port for Standard Size 3) P Max [bar] 4) State 8)
    A , B Working port   see port plates 450  
    T 1 Drain port DIN 3852 5) M18 x 1.5 deep 12 3 X 7)
    T 2 Drain port DIN 3852 5) M18 x 1.5 deep 12 3 O 7)

    image.png

    Plate Ports Port for Standard Size 1) P Max [bar] 2) State 5)
    01, 02, 10 A , B

    Working port

    Fastening thread

    SAE J518 4)

    DIN 13

    3/4”

    M10 x 1.5 deep 17

    450 O

    Note

    1) For the maximum tightening torques the general instructions must be observed .

    2) Momentary pressure spikes may occur depending on the application. Keep this in mind when selecting measuring devices and fittings.

    4) Only dimensions according to SAE J518, metric fastening thread is a deviation from standard.

    5) O = Must be connected (plugged on delivery)   X = plugged (in normal operation)

     

    image.png

    Ports Port for Standard Size 3) P Max [bar] 4) State 8)
    A , B Working port   see port plates 450  
    T 1 Drain port DIN 3852 5) M18 x 1.5 deep 12 3 X 7)
    T 2 Drain port DIN 3852 5) M18 x 1.5 deep 12 3 O 7)

    image.png

    Plate Ports Port for Standard Size 1) P Max [bar] 2) State 5)
    01, 10 A , B

    Working port

    Fastening thread

    SAE J518 4)

    DIN 13

    1- 1/4”

    M14 x 2 deep 19

    450 O

    02

    Size107

    A , B

    Working port

    Fastening thread

    SAE J518 4)

    DIN 13

    1”

    M12 x 1.75 deep 17

    450 O

    02

    Size125

    A , B

    Working port

    Fastening thread

    SAE J518 4)

    DIN 13

    1- 1/4”

    M14 x 2 deep 19

    450 O

    Note

    1) For the maximum tightening torques the general instructions must be observed .

    2) Momentary pressure spikes may occur depending on the application. Keep this in mind when selecting measuring devices and fittings.

    4) Only dimensions according to SAE J518, metric fastening thread is a deviation from standard.

    5) O = Must be connected (plugged on delivery)   X = plugged (in normal operation)

    image.png

    Ports Port for Standard Size 3) P Max [bar] 4) State 8)
    A , B Working port   see port plates 450  
    T 1 Drain port DIN 3852 5) M22 x 1.5 deep 14 3 X 7)
    T 2 Drain port DIN 3852 5) M22 x 1.5 deep 14 3 O 7)

    Axial Piston Fixed Pump HD-A2FM 29Axial Piston Fixed Pump HD-A2FM 30Axial Piston Fixed Pump HD-A2FM 31Note

    1) To shaft colla

    2) Center bore according to DIN 332 (thread according to DIN 13)

    3) For the maximum tightening torques the general instructions must be observed .

    4) Momentary pressure spikes may occur depending on the application. Keep this in mind when selecting measuring devices and fittings.

    5) The spot face can be deeper than specified in the appropriate standard

    7) Depending on the installation position, T1 or T2 must be connected

    8) O = Must be connected (plugged on delivery) X = plugged (in normal operation)

     

    image.png

    Plate Ports Port for Standard Size 1) P Max [bar] 2) State 5)
    01, 02, 10 A , B

    Working port

    Fastening thread

    SAE J518 4)

    DIN 13

    1- 1/4”

    M14 x 2 deep 19

    450 O

     

    Note

    1) For the maximum tightening torques the general instructions must be observed .

    2) Momentary pressure spikes may occur depending on the application. Keep this in mind when selecting measuring devices and fittings.

    4) Only dimensions according to SAE J518, metric fastening thread is a deviation from standard.

    5) O = Must be connected (plugged on delivery)   X = plugged (in normal operation)

    image.png

    Axial Piston Fixed Pump HD-A2FM 34Ports Port for Standard Size 3) P Max [bar] 4) State 8)
    A , B

    Working port

    Fastening thread

    SAE J518 6)

    DIN 13

    1- 1/4”

    M14 x 2deep 19

    450  
    T 1 Drain port DIN 3852 5) M22 x 1.5 deep 14 3 X 7)
    T 2 Drain port DIN 3852 5) M22 x 1.5 deep 14 3 O 7)

    Note

    1) To shaft colla

    2) Center bore according to DIN 332 (thread according to DIN 13)

    3) For the maximum tightening torques the general instructions must be observed .

    4) Momentary pressure spikes may occur depending on the application. Keep this in mind when selecting measuring devices and fittings.

    5) The spot face can be deeper than specified in the appropriate standard

    6) Only dimensions according to SAE J518, metric fastening thread is a deviation from standard.

    7) Depending on the installation position, T1 or T2 must be connected

    8) O = Must be connected (plugged on delivery)   X = plugged (in normal operation)

    image.png

    Ports Port for Standard Size 3) P Max [bar] 4) State 8)
    A , B Working port   see port plates 450  
    T 1 Drain port DIN 3852 5) M22 x 1.5 deep 14 3 X 7)
    T 2 Drain port DIN 3852 5) M22 x 1.5 deep 14 3 O 7)
    U Bearing flushing port DIN 3852 5) M14 x 1.5 deep 12 3 X

    Axial Piston Fixed Pump HD-A2FM 36Axial Piston Fixed Pump HD-A2FM 37Note

    1) To shaft colla

    2) Center bore according to DIN 332 (thread according to DIN 13)

    3) For the maximum tightening torques the general instructions must be observed . 4) Momentary pressure spikes may occur depending on the application. Keep this in mind when selecting measuring devices and fittings.

    5) The spot face can be deeper than specified in the appropriate standard

    7) Depending on the installation position, T1 or T2 must be connected

    8) O = Must be connected (plugged on delivery) X = plugged (in normal operation)

    image.png

    Plate Ports Port for Standard Size 1) P Max  [bar] 2) State 5)
    01, 02 A , B

    Working port

    Fastening thread

    SAE J518 4)

    DIN 13

    1- 1/4”

    M14 x 2 deep  19

    400 O

    Note

    1) For the maximum tightening torques the general instructions must be observed .

    2) Momentary pressure spikes may occur depending on the application. Keep this in mind when selecting measuring devices and fittings.
     

    4) Only dimensions according to SAE J518, metric fastening thread is a deviation from standard.

    5) O = Must be connected (plugged on delivery)   X = plugged (in normal operation)

    image.png

    Ports Port for Standard Size 3) P Max [bar] 4) State 8)
    A , B

    Working port

    Fastening thread

    SAE J518 6)

    DIN 13

    1- 1/2”

    M16 x 2 deep 21

    450  
    T 1 Drain port DIN 3852 5) M33 x 2 deep 18 3 X 7)
    T 2 Drain port DIN 3852 5) M33 x 2 deep 18 3 O 7)
    U Bearing flushing port DIN 3852 5) M14 x 1.5 deep 12 3 X
    M A, MB Measuring workting pressure DIN 3852 5) M14 x 1.5 deep 12 400 X

     

    image.png

    Ports Port for Standard Size 3) P Max [bar] 4) State 8)
    A , B

    Working port

    Fastening thread

    SAE J518 6)

    DIN 13

    1- 1/2”

    M16 x 2 deep 21

    450  
    T 1 Drain port DIN 3852 5) M33 x 2 deep 18 3 X 7)
    T 2 Drain port DIN 3852 5) M33 x 2 deep 18 3 O 7)
    U Bearing flushing port DIN 3852 5) M18 x 1.5 deep 12 3 X
    M A, MB Measuring workting pressure DIN 3852 5) M14 x 1.5 deep 12 400 X

    HD-A2FM Axial Piston Fixed Motor Attachment

    image.png

     

    Flushing and boost pressure valve dimensions in mm

     

    image.png

    image.png

    Pressure-relief valve dimensions in mm

    Size Code D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D132)
    28 , 32 MHDB16 209 186 25 68 174 102 87 36 66 50.8 23.8 Φ19 M10 deep 17
    45 MHDB16 222 198 22 65 187 113 98 36 66 50.8 23.8 Φ19 M10 deep 17
    56 , 63 MHDB22 250 222 19 61 208 124 105 42 75 50.8 23.8 Φ19 M10 deep 13
    80 , 90 MHDB22 271 243 17.5 59 229 134 114 42 75 57.2 27.8 Φ25 M12 deep 18
    107 , 125 MHDB32 298 266 10 52 250 149.5 130 53 84 66.7 31.8 Φ32 M14 deep 19
    160 , 180 MHDB32 332 301 5 47 285 170 149 53 84 66.7 31.8 Φ32 M14 deep 19

     

    Size Port A ,B S11) M A, M B1) P St1)  
    28 , 32 3/4” M22 x 1.5 deep 14 M20 x 1.5 deep 14 G1/4” Assembly instructions for port plate with pressure boost facility "192"The lock nut must be counterheld when  installing the hydraulic line at the pst port
    45 3/4” M22 x 1.5 deep 14 M20 x 1.5 deep 14 G1/4”
    56 , 63 3/4” M26 x 1.5 deep 16 M26 x 1.5 deep 16 G1/4”
    80 , 90 1” M26 x 1.5 deep 16 M26 x 1.5 deep 16 G1/4”
    107 , 125 1- 1/4” M26 x 1.5 deep 16 M26 x 1.5 deep 16 G1/4”
    160 , 180 1- 1/4” M26 x 1.5 deep 16 M30 x 1.5 deep 16 G1/4”
    Ports Port for Standard Size 1) P Max [bar] 2) State 3)
    A , B Working port SAE J518 See above 450 O
    S1 Supply port (only with port plate 191/192) DIN 3852 See above 5 O
    M A, M B Measuring operating pressure port DIN 3852 See above 450 X
    P St Pilot pressure port (only with port plate 192) DIN 3852 See above 30 O

     

    Counterbalance valve BVD and BVE

    Travel drive/winch counterbalance valves are designed to reduce the danger of overspeeding and cavitation of axial piston motors in open circuits. 

    Cavitation occurs if the motor speed is greater than it should be for the given input flow while braking, travelling downhill, or lowering a load.

    If the inlet pressure drops, the counterbalance spool throttles the return flow and brakes the motor until the inlet pressure returns to approx. 20 bar

    BVD available for sizes 28 to 180 and BVE available for sizes 107 to 180.

    The counterbalance valve must be ordered additionally. We recommend ordering the counterbalance valve and the motor as a set.

     Note

    Ordering example

    A2FM90/61W–VAB188 + BVD20F27S/41B–V03K16D0400S12

    The counterbalance valve does not replace the mechanical service brake and park brake.

    Observe the detailed notes on the BVD counterbalance valve and BVE counterbalance valve

    For the design of the brake release valve, we must know for the mechanical park brake the pressure at the start of opening

    The volume of the counterbalance spool between minimum stroke (brake closed) and maximum stroke (brake released with 21 bar)

    The required closing time for a warm device (oil viscosity approx 15 mm2/s)

    Technical Data

    Permissible input flow or pressure in operation with DBV and BVD/BE

    Motor Without valve

    Restricted values 

    in operation with DBV

    Restricted values in 

    operation with BVD/BVE

    HD-A2FM Pnom/Pmax qv max DBV Pnom/Pmax qv max Plate BVD/BVE Pnom/Pmax qv max Plate
    Size bar l/min size bar l/min Code size bar I/min Code
    28 400/450 176 16 350/420 100

    181

    191 , 192

    20

    BVD

    350/420 100 188
    32 201
    45 255
    56 280 22 240 220
    63 315
    80 360
    90 405
    107 427 171 ,191 , 192 178
    125 500
    107 427 32 400 181,191 , 192 25 BVD/BVE 320 188

    image.png

     

    HD-A2FM Counterbalance valve Dimensions in mm
    Size Type Port A, B B1 B2 B3 B4(S) B4(L) B5 B6 B7
    28 , 32 BVD20 … 16 3/4” 209 175 174 142 147 139 98 66
    45 BVD20 … 16 3/4” 222 196 187 142 147 139 98 66
    56 , 63 BVD20 … 17 3/4” 250 197 208 142 147 139 98 75
    80 , 90 BVD20 …27 1” 271 207 229 142 147 139 98 75
    107 , 125 BVD20 …28 1” 298 238 251 142 147 139 98 84
    107 , 125 BVD25 …38 1- 1/4” 298 239 251 158 163 175 120.5 84
    160 , 180 BVD25 …38 1- 1/4” 332 260 285 158 163 175 120.5 84
    107 , 125 BVE25 … 38 1- 1/4” 298 240 251 167 172 214 137 84
    160 , 180 BVE25 … 38 1- 1/4” 332 260 285 167 172 214 137 84
    250 On request

     

     

     

    Ports Port for           Version                                       Standard Size 1) P Max [bar] 2) State4)
    A , B Working port SAE J518 See above 420 O
    S BVD20,BVD25, BVE25 DIN 3852 3) M22 x 1.5 deep 14 30 X
    DIN 3852 3) M27 x 2 deep 16 30 X
    Br Brake release,reduce high pressure      L DIN 3852 3) M12 x 1.5 deep 12.5 30 O
    Gext Brake release,high pressure       S                 DIN 3852 3) M12 x 1.5 deep 12.5 420 X
    M A, MB Measuring pressure A, B ISO 6149 3) M12 x 1.5 deep 12 420 X

    Note

    1) For the maximum tightening torques the general instructions must be observed .

    2) Momentary pressure spikes may occur depending on the application. Keep this in mind when selecting measuring devices and fittings.

    3) The spot face can be deeper than specified in the appropriate standard

    4) O = Must be connected (plugged on delivery)   X = plugged (in normal operation)

    image.png

    image.png

    image.png

    Technical Information

    Hydraulic fluid

    Before starting project planning, please refer to our data sheets mineral oil and environmentally acceptable hydraulic fluids for detailed information regarding the choice of hydraulic fluid and application conditions.

    When using environmentally acceptable hydraulic fluids, the limitations regarding technical data and seals must be observed.

    Please contact us. When ordering, indicate the hydraulic fluid that is to be used.

    Notes on the choice of hydraulic fluid

    In order to select the correct hydraulic fluid, it is necessary to know the operating temperature in the reservoir (open circuit) in relation to the ambient temperature.

    The hydraulic fluid should be selected so that within the operating temperature range, the viscosity lies within the optimum range (nopt), see shaded section of the selection diagram. We recommend to select the higher viscosity grade in each case.

    Example: at an ambient temperature of X ℃ the operating temperature is 60℃. In the optimum operating viscosity range (Vopt; shaded area) this corresponds to viscosity grades VG 46 resp. VG 68; VG 68 should be selected.

    Important

    The case drain temperature is influenced by pressure and input speed and is always higher than the reservoir temperature.

    However, at no point in the component may the temperature exceed 90℃. The temperature difference specified on the left is to be taken into account when determining the viscosity in the bearing

    If the above conditions cannot be met, due to extreme operating parameters please contact us.

    Filtration of the hydraulic fluid

    The finer the filtration the better the cleanliness level of the hydraulic fluid and the longer the service life of the axial piston unit.

    In order to guarantee the functional reliability of the axial piston unit it is necessary to carry out a gravimetric evaluation of the hydraulic fluid to determine the particle contamination and the cleanliness level according to ISO 4406.

    A cleanliness level of at least 20/18/15 must be maintained.

    At very high hydraulic fluid temperatures (90℃ to maximum 115℃), a cleanliness level of at least 19/17/14 according to ISO 4406 is necessary.

    If the above cleanliness levels cannot be maintained, contact us.

     

    Viscosity and temperature of hydraulic fluids

      Viscosity Shaft seal Temperature 3) Comment
    Cold start Vmax  ≤1600 mm2/s

    NBR 2)

    FKM

    θSt  ≥ -40℃

    θSt  ≥ -25℃

    t ≤3 min, without load (P ≤ 50 bar) n≤1000 rpm                 

    Permissible temperature difference between axial piston unit and hydraulic fluid in the system maximum 25 K

    Warm-up phase V = 1600~400 mm2/s     t ≤15 min,P ≤0.7*P nom and n ≤ 0.5*n nom

    Continuous

    operation

    V = 400~10 mm2/s1)

    NBR 2)

    FKM

    θ= +85℃

    T = +110℃

    measured at port L, L1
    V = 36~16 mm2/s     Range of optimum operating viscosity and efciency

    Short-term

    operation

    V = 10~7 mm2/s

    NBR 2)

    FKM

    θ = +85℃

    θ = +110℃

    t ≤3 min,P ≤0.3*P nom   measured at port L, L1

    1)Corresponds e.g. for VG 46 to a temperature range of +4 °C to +85 °C (see selection diagram)   

     2)Version EA10VSO...-P (if operating with HFA, HFB and HFC hydraulic fluids)

    3)If the temperature at extreme operating parameters cannot be adhered to, please contact us

     

    Selection diagram

    image.png

    General instructions

     The pump HD-A2FO is designed to be used in open circuits. The motor HD-A2FM/E is designed to be used in open and closedcircuits.

     The project planning, installation and commissioning of the axial piston unit requires the involvement of qualified personnel.

     Before using the axial piston unit, please read the corresponding instruction manual completely and thoroughly.

     During and shortly after operation, there is a risk of burns on the axial piston unit. Take appropriate safety measures (e.g. by wearing protective clothing).

     Depending on the operating conditions of the axial piston unit (operating pressure, fluid temperature), the characteristic may shift.

    Service line ports

    The ports and fastening threads are designed for the specified maximum pressure.

    The machine or system manufacturer must ensure that the connecting elements and lines correspond to the specified application conditions (pressure, flow, hydraulic fluid, temperature) with the necessary safety factors.

    The service line ports and function ports can only be used to accommodate hydraulic lines.

    The data and notes contained herein must be adhered to.

    The product is not approved as a component for the safety concept of a general machine according to ISO 13849.

    The following tightening torques apply

    Fittings

    Observe the manufacturer's instructions regarding tightening torques of the fittings used

    Mounting bolts

    For mounting bolts with metric ISO thread according to DIN 13 or with thread according to ASME B1.1, we recommend checking the tightening torque in individual cases in accordance with VDI 2230.

    Female threads in the axial piston unit

    The maximum permissible tightening torques MG max are maximum values for the female threads and must not be exceeded. For values, see the following table.

    Threaded plugs

    For the metallic threaded plugs supplied with the axial piston unit, the required tightening torques of threaded plugs MV apply. For values, see the following table.

    Ports Maximum permissible tightening torque of the female threads M Gmax

    Required tightening

    torque of the 

    threaded plugs Mv1)

    hexagon socket in the 

    threaded plugs WAF

    Standard Size of thread
    DIN 3852 M8 x 1 10 Nm 7 Nm 3 mm
    M10 x 1 30 Nm 12 Nm 5 mm
    M12 x 1.5 50 Nm 25 Nm 2) 6 mm
    M14 x 1.5 80 Nm 35 Nm 6 mm
    M16 x 1.5 100 Nm 50 Nm 8 mm
    M18 x 1.5 140 Nm 60 Nm 8 mm
    M22 x 1.5 210 Nm 80 Nm 10 mm
    M26 x 1.5 230 Nm 120 Nm 12 mm
    M27 x 2 330 Nm 135 Nm 12 mm
    M33 x 2 540 Nm 225 Nm 17 mm
    M42 x 2 720 Nm 360 Nm 22 mm
    DIN ISO 228 G1/4” 40 Nm - -

    Note

    1) The tightening torques apply for screws in the "dry" state as received on delivery and in the "lightly oiled" state for installation.

    2) In the "lightly oiled" state, the MV is reduced to 10 Nm for M10 x 1 and 17 Nm for M12 x 1.5.

     

    Related Products
    no data
    Contact us
    Do you have a question?
    Experience seamless assistance from our team of Trade Account Managers with everything from quotes to delivery and everything in between for your project. Our trade experts are here to help.
    You Can Find Us Here
    S10-6-5, Water Port Function area, l Lan Glu-C UN Tan Free Trade Port Area, Jiang B EI District, Chongqing
    ChangJia is a global leader in hydraulic technology, integrating R&D, manufacturing, sales, and service to drive innovation and production of core hydraulic components.

     Public Mailbox: info@changjia.com

    Contact us

    Tina
    Tel: +86 135 0836 3447
    WhatsApp: +86 135 0836 3447
    Email: tina@changjia.com
    Anne
    Tel: +86 158 2639 0716
    WhatsApp: +86 158 2639 0716
    Email: anne@changjia.com
    no data
    Copyright © 2026 CHANGJIA COMPANY
    Customer service
    detect